Abstract

In this study, radiotherapy simulations were studied using Carbon-12 (12C) ion source. For this purpose, radiation dose distribution in water was investigated by bombarding water with 12C ions in different energies. As energies of 12C ions were increased, the maximum dose region occurred in more depth. Then, water was bombarded with 12C by placing different materials on the surface of the water, and radiation dose distribution in water was studied. The thickness of material placed in front of the surface of water changed the location of maximum radiation dose region. This trend provided the opportunity to be able to create a maximum dose region of what we wanted in water by using a mono-energetic source. For derivation of dose distribution, Gate/Geant4 program was used.  

References

Sedrak MS, Freedman RA, Cohen HJ, Muss HB, Jatoi A, Klepin HD, et al. Older adult participation in cancer clinical trials: a systematic review of barriers and interventions. CA: A Cancer Journal for Clinicians. 2021;71:78-92.

Farahbakhsh Z, Zamani MR, Rafienia M, Gülseren O, Mirzaei M. In silico activity of AS1411 aptamer against nucleolin of cancer cells. Iranian Journal of Blood and Cancer. 2020;12:95-100.

Mirzaei M, Gulseren O, Rafienia M, Zare A. Nanocarbon-assisted biosensor for diagnosis of exhaled biomarkers of lung cancer: DFT approach. Eurasian Chemical Communications. 2021;3:154-161.

Mirzaei M, Gülseren O, Hadipour N. DFT explorations of quadrupole coupling constants for planar 5-fluorouracil pairs. Computational and Theoretical Chemistry. 2016;1090:67-73.

Kakaei A, Mirzaei M. Cyclophosphamide@ CNT: in silico exploration of nano drug delivery system. Lab-in-Silico. 2021;2:9-14.

Kraft G, Weber U. Tumor therapy with ion beams. Handbook of Particle Detection and Imaging. 2012:1179-1205.

Peukert D, Kempson I, Douglass M, Bezak E. Metallic nanoparticle radiosensitisation of ion radiotherapy: a review. Physica Medica. 2018;47:121-128.

Rackwitz T, Debus J. Clinical applications of proton and carbon ion therapy. Seminars in Oncology. 2019;46:226-232.

Andreo P. Monte Carlo simulations in radiotherapy dosimetry. Radiation Oncology. 2018;13:1-5.

Ou HF, Zhang B, Zhao SJ. Gate/Geant4-based Monte Carlo simulation for calculation of dose distribution of 400 MeV/u carbon ion beam and fragments in water. Nuclear Science and Techniques. 2016;27:1-7.

Mirzaei M. Making sense the ideas in silico. Lab-in-Silico. 2020;1:31-32.

Harrison RL. Simulation of medical imaging systems: emission and transmission tomography. Handbook of Particle Detection and Imaging. 2012:1095-1124.

Sarrut D, Bardiès M, Boussion N, Freud N, Jan S, Létang JM, et al. A review of the use and potential of the GATE Monte Carlo simulation code for radiation therapy and dosimetry applications. Medical Physics. 2014;41:064301.

Tchelebi LT, Lehrer EJ, Trifiletti DM, Sharma NK, Gusani NJ, Crane CH, Zaorsky NG. Conventionally fractionated radiation therapy versus stereotactic body radiation therapy for locally advanced pancreatic cancer (CRiSP): an international systematic review and meta?analysis. Cancer. 2020;126:2120-2131.

Zhao Q, Liu Y, Zhang Y, Meng L, Wei J, Wang B, Wang H, Xin Y, Dong L, Jiang X. Role and toxicity of radiation therapy in neuroblastoma patients: a literature review. Critical Reviews in Oncology/Hematology. 2020;149:102924.

Chen X, Gole J, Gore A, He Q, Lu M, Min J, et al. Non-invasive early detection of cancer four years before conventional diagnosis using a blood test. Nature Communications. 2020;11:1-10.

Son S, Kim JH, Wang X, Zhang C, Yoon SA, Shin J, et al. Multifunctional sonosensitizers in sonodynamic cancer therapy. Chemical Society Reviews. 2020;49:3244-3261.

Yaraghi A, Ozkendir OM, Mirzaei M. DFT studies of 5-fluorouracil tautomers on a silicon graphene nanosheet. Superlattices and Microstructures. 2015;85:784-788.

Jan S, Santin G, Strul D, Staelens S, Assie K, Autret D, et al. GATE: a simulation toolkit for PET and SPECT. Physics in Medicine & Biology. 2004;49:4543.

Antcheva I, Ballintijn M, Bellenot B, Biskup M, Brun R, Buncic N, et al. ROOT-A C++ framework for petabyte data storage, statistical analysis and visualization. Computer Physics Communications. 2009;180:2499-2512.

Giahi M, Mirzaei M, Meskinfam M, Yousefi M. Density functional studies of the fluorine-terminated boron nitride nanotubes through computations of quadrupole coupling constants. Computational and Theoretical Chemistry. 2011;977:29-33.

Bodaghi A, Mirzaei M, Seif A, Giahi M. A computational NMR study on zigzag aluminum nitride nanotubes. Physica E. 2008;41:209-212.

Sun C, Wu F, Wallis DJ, Shen MH, Yuan F, Yang J, et al. Gallium nitride: a versatile compound semiconductor as novel piezoelectric film for acoustic tweezer in manipulation of cancer cells. IEEE Transactions on Electron Devices. 2020;67:3355-3361.

Pécz B, Nicotra G, Giannazzo F, Yakimova R, Koos A, Kakanakova?Georgieva A. Indium nitride at the 2D limit. Advanced Materials. 2021;33:2006660.

Rai A, Noor S, Ahmad SI, Alajmi MF, Hussain A, Abbas H, Hasan GM. Recent advances and implication of bioengineered nanomaterials in cancer theranostics. Medicina. 2021;57:91.

Downloads

Published

2021-03-30

How to Cite

Topakli, H., & Emur, M. (2021). Gate/Geant4 Dose Distribution Simulation with Carbon-12 Ion Source in Water. Advanced Journal of Science and Engineering, 2(1), 36–41. https://doi.org/10.22034/advjscieng21021036

Issue

Section

Original Research Article